All Elcometer 456 Coating Thickness Gauge probes are fully interchangeable and are available in a number of designs and scale ranges to meet your specific application.
Ferrous Probes (F)
- Ferrous probes measure non-magnetic coatings on ferromagnetic substrates
- Elcometer 456 ferrous gauges accept any ferrous probe
Non-Ferrous Probes (N)
- Non-ferrous probes measure non-conductive coatings on non-ferrous metal substrates
- Elcometer 456 non-ferrous gauges accept any non-ferrous probe
Dual Probes (FNF)
- Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection
- Elcometer 456 FNF gauges accept all ferrous, non-ferrous and dual FNF probes
High Temperature
- Elcometer probes have a maximum operating temperature of 80°C (176°F)*
- Separate ferrous probes have a maximum operating temperature of 150°C (300°F)*
- Hi-Temperature PINIP™ has a maximum operating temperature of 250°C (480°F)*
*The stated temperature is the substrate temperature, and the duty cycle of the probe must be reduced to ensure a minimal temperature build-up within the probe.
Summary
Elcometer 456 Coating Thickness Gauge Probe Range
Ferrous coating thickness gauge probes measure non magnetic coatings on ferro-magnetic substrates. Elcometer 456 coating thickness ferrous gauges accept any ferrous probe.
Non-ferrous coating thickness gauge probes measure non conductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe.
Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. Elcometer 456 FNF coating thickness gauges accept all ferrous, non-ferrous and dual FNF probes.
Key Features
Elcometer 456 Coating Thickness Gauge Probe Range
Straight Probes
Standard Straight Probe
Standard probes measure coatings on both flat and curved surfaces.
Anodising Probe
Chemical resistant & washable – ideal for the anodising environment.
Mini Probe
Mini probes are ideal for harder to reach areas and edges.
Waterproof Probe
Sealed for use underwater at depth, even in diving gloves.
Soft Coating Probe
Large surface area probes are for soft materials (HVCA approved).
Thick Coatings Probe
Ideal for measuring coatings up to 31mm thick.
Scan Probes
Standard Scan Probe
Rapidly scan large surface areas without damaging the probe or the coating.
Ball Bearing Scan Probe
Clip on adaptors for large coated structures, abrasive coatings and pre-construction primers.
Angled Probes
Right Angle Probe
Take readings in areas with restricted clearance.
Mini Right Angle Probe
For measuring coatings on edges, narrow pipes or small surface areas.
Telescopic Probe
Extending probes for hard to reach areas.
45° Angle Probe
Measure difficult to access or complex areas.
Plug In Integral Probes (PINIP™)
PINIP™ Integral Probe
Transforms a separate gauge into an integral gauge, ideal for single-handed use.
Hi-Temperature PINIP™
Measure coatings on ferrous substrates up to 250°C (480°F).
Armoured Cable Probes
F / FNF Armoured Probe
Reinforced heavy duty cables reduce the risk of cable damage.
Scale 0.5: Range : 0-500μm (0-20mils) | |||||
Accuracya | (±1-3% or ±0.1mil) | ||||
Range | 0-500μm (0-20mils) | ||||
Resolution | 0.1μm: 0-100μm (0.01mil: 0-5mils) 1μm: 100-500μm (0.1mil: 5-20mils) |
||||
Certificate | |||||
Description | Part Number | Minimum Headroom | Minimum Sample Diameterb | Minimum Convex Surface Diameter | Minimum Concave Surface Radius |
Ferrous (F) | |||||
Straight Mini Probe Probe Length: 45mm (1.77”)c |
T456CFM3—A | 6mm (0.24”) | 3mm (0.12”) | 1.9mm (0.07″) | 6.5mm (0.26″) |
Right Angle Mini Probe Probe Length: 45mm (1.77”)c |
T456CFM3R90A | 16mm (0.63”) | 3mm (0.12”) | 1.9mm (0.07″) | 6.5mm (0.26″) |
45° Angle Mini Probe Probe Length: 45mm (1.77”)c |
T456CFM3R45A | 16mm (0.63”) | 3mm (0.12”) | 1.9mm (0.07″) | 6.5mm (0.26″) |
Straight Mini Probe Probe Length: 150mm (5.90”)c |
T456CFM3—C | 6mm (0.24”) | 3mm (0.12”) | 1.9mm (0.07″) | 6.5mm (0.26″) |
Right Angle Mini Probe Probe Length: 150mm (5.90”)c |
T456CFM3R90C | 16mm (0.63”) | 3mm (0.12”) | 1.9mm (0.07″) | 6.5mm (0.26″) |
45° Angle Mini Probe Probe Length: 300mm (11.80”)c |
T456CFM3R45D | 18mm (0.71”) | 3mm (0.12”) | 1.9mm (0.07″) | 6.5mm (0.26″) |
Right Angle Mini Probe Probe Length: 300mm (11.80”)c |
T456CFM3R90D | 16mm (0.63”) | 3mm (0.12”) | 1.9mm (0.07″) | 6.5mm (0.26″) |
Non-Ferrous (N) | |||||
Straight Mini Probe Probe Length: 45mm (1.77”)c |
T456CNM3—A | 6mm (0.24”) | 4mm (0.16”) | 6mm (0.24″) | 8.5mm (0.33″) |
Right Angle Mini Probe Probe Length: 45mm (1.77”)c |
T456CNM3R90A | 16mm (0.63”) | 4mm (0.16”) | 6mm (0.24″) | 8.5mm (0.33″) |
Straight Mini Probe Probe Length: 150mm (5.90”)c |
T456CNM3—C | 6mm (0.24”) | 4mm (0.16”) | 6mm (0.24″) | 8.5mm (0.33″) |
Right Angle Mini Probe Probe Length: 150mm (5.90”)c |
T456CNM3R90C | 16mm (0.63”) | 4mm (0.16”) | 6mm (0.24″) | 8.5mm (0.33″) |
Right Angle Mini Probe Probe Length: 400mm (15.70”)c |
T456CNM3R90E | 16mm (0.63”) | 4mm (0.16”) | 6mm (0.24″) | 8.5mm (0.33″) |
Non-Ferrous – Graphite (N) | |||||
Right Angle Mini Probe Probe Length: 45mm (1.77”)c |
T456CNMG3R90A | 16mm (0.63”) | 4mm (0.16”) | 6mm (0.24″) | 8.5mm (0.33″) |
Right Angle Mini Probe Probe Length: 150mm (5.90”)c |
T456CNMG3R90C | 16mm (0.63”) | 4mm (0.16”) | 6mm (0.24″) | 8.5mm (0.33″) |
Right Angle Mini Probe Probe Length: 400mm (15.70”)c |
T456CNMG3R90E | 16mm (0.63”) | 4mm (0.16”) | 6mm (0.24″) | 8.5mm (0.33″) |
Scale 1: Range : 0-1500μm (0-60mils) | |||||
Accuracyae | ±1-3% or ±2.5μm (±1-3% or ±0.1mil) | ||||
Ranged | 0-1500μm (0-60mils) | ||||
Resolution | 0.1μm: 0-100μm (0.01mil: 0-5mils) 1μm: 100-1500μm (0.1mil: 5-60mils) |
||||
Certificate | |||||
Description | Part Number | Minimum Headroom | Minimum Sample Diameterb | Minimum Convex Surface Diameter | Minimum Concave Surface Radius |
Ferrous (F) | |||||
Straight Probe Probe Length: 45mm (1.77”)c |
T456CF1S | 85mm (3.35”) | 4mm (0.16”) | 4mm (0.16″) | 25mm (0.98″) |
Straight Probe – sealed Probe Length: 45mm (1.77”)c |
T456CF1E | 85mm (3.35”) | 4mm (0.16”) | 4mm (0.16″) | 25mm (0.98″) |
Scan Probe Probe Length: 45mm (1.77”)c |
T456CF1U | 86mm (3.38”) | 15mm (0.59”) | Flat Surface | Flat Surface |
Scan Probe – armoured Probe Length: 45mm (1.77”)c |
T456CF1UARM | 140mm (5.51”) | 15mm (0.59”) | Flat Surface | Flat Surface |
90° Probe Probe Length: 45mm (1.77”)c |
T456CF1R | 28mm (1.10”) | 4mm (0.16”) | 4mm (0.16″) | 25mm (0.98″) |
90° Mini Probe Probe Length: 45mm (1.77”)c |
T456CFM5R90A | 16mm (0.63”) | 4mm (0.16”) | 3mm (0.12″) | 6.5mm (0.26″) |
90° Mini Probe – sealed Probe Length: 45mm (1.77”)c |
T456CFME5R90A | 16mm (0.63”) | 4mm (0.16”) | 3mm (0.12″) | 6.5mm (0.26″) |
90° Mini Probe – sealed, 2m cable Probe Length: 45mm (1.77”)c |
T456CFME5R90A-2 | 16mm (0.63”) | 4mm (0.16”) | 3mm (0.12″) | 6.5mm (0.26″) |
PINIP™ Integral Probe | T456CF1P | 170mm (6.69”) | 4mm (0.16”) | 4mm (0.16″) | 60mm (2.36″) |
Non-Ferrous (N) | |||||
Straight Probe Probe Length: 45mm (1.77”)c |
T456CN1S | 85mm (3.35”) | 4mm (0.16”) | 10mm (0.39″) | 10mm (0.39″) |
90° Probe Probe Length: 45mm (1.77”)c |
T456CN1R | 28mm (1.10”) | 4mm (0.16”) | 10mm (0.39″) | 14mm (0.55″) |
Mini 90° Probe Probe Length: 45mm (1.77”)c |
T456CNM5R90A | 16mm (0.63”) | 4mm (0.16”) | 10mm (0.39″) | 8.5mm (0.33″) |
Mini 90°Probe Probe Length: 150mm (5.90”)c |
T456CNM5R90C | 16mm (0.63”) | 4mm (0.16”) | 10mm (0.39″) | 8.5mm (0.33″) |
Mini 90° Probe Probe Length: 400mm (15.7”)c |
T456CNM5R90E | 16mm (0.63”) | 4mm (0.16”) | 10mm (0.39″) | 8.5mm (0.33″) |
Anodiser Probe Probe Length: 45mm (1.77”)c |
T456CN1AS | 100mm (3.94”) | 4mm (0.16”) | 10mm (0.39″) | 14mm (0.55″) |
PINIP™ Integral Probe | T456CN1P | 180mm (7.09”) | 4mm (0.16”) | 10mm (0.39″) | 50mm (1.97″) |
Ferrous & Non-Ferrous (FNF) | |||||
Straight Probe Probe Length: 45mm (1.77”)c |
T456CFNF1S | 88mm (3.46”) | F: 4mm (0.16”), N: 6mm (0.24”) | F: 4mm (0.16″) N: 26mm (1.02″) |
12.5mm (0.49″) |
Straight Probe – armoured cable Probe Length: 45mm (1.77”)c |
T456CFNF1ARM | 185mm (7.28″) | F: 4mm (0.16”), N: 6mm (0.24”) | F: 4mm (0.16″) N: 26mm (1.02″) |
12.5mm (0.49″) |
Scan Probe Probe Length: 45mm (1.77”)c |
T456CFNF1U | 89mm (3.50”) | 15mm (0.59”) | Flat Surface | Flat Surface |
Right Angle Probe Probe Length: 45mm (1.77”)c |
T456CFNF1R | 38mm (1.50”) | F: 4mm (0.16”), N: 6mm (0.24”) | F: 4mm (0.16″) N: 26mm (1.02″) |
12.5mm (0.49″) |
PINIP™ Integral Probe | T456CFNF1P | 180mm (7.09”) | F: 4mm (0.16”), N: 6mm (0.24”) | F: 4mm (0.16″) N: 26mm (1.02″) |
65mm (2.56″) |
Scale 2: Range : 0-5mm (0-200mils) | |||||
Accuracyae | ±1-3% or ±20μm (±1-3% or ±1.0mil) | ||||
Ranged | 0-5mm (0-200mils) | ||||
Resolution | 1μm: 0-1mm (0.1mil: 0-50mils) 10μm: 1-5mm (1.0mil: 50-200mils) |
||||
Certificate | |||||
Description | Part Number | Minimum Headroom | Minimum Sample Diameterb | Minimum Convex Surface Diameter | Minimum Concave Surface Radius |
Ferrous (F) | |||||
Straight Probe Probe Length: 45mm (1.77”)c |
T456CF2S | 89mm (3.50”) | 8mm (0.32”) | 4mm (0.16″) | 25mm (0.98″) |
Scan Probe Probe Length: 45mm (1.77”)c |
T456CF2U | 90mm (3.54”) | 15mm (0.59”) | Flat Surface | Flat Surface |
90° Probe Probe Length: 45mm (1.77”)c |
T456CF2R | 32mm (1.26”) | 8mm (0.32”) | 4mm (0.16″) | 25mm (0.98″) |
Straight Probe – armoured cable Probe Length: 45mm (1.77”)c |
T456CF2ARM | 138mm (5.43”) | 8mm (0.32”) | 4mm (0.16″) | 25mm (0.98″) |
Telescopic Probe Probe Length: 56-122cm (22-48”)c |
T456CF2T | 36mm (1.42”) | 8mm (0.32”) | 4mm (0.16″) | 25mm (0.98″) |
Soft Coating Probe Probe Length: 45mm (1.77”)c |
T456CF2B | 89mm (3.50”) | 8mm (0.32”) | Flat Surface | Flat Surface |
Waterproof Probe – 1m (3’) cable Probe Length: 45mm (1.77”)c |
T456CF2SW | 138mm (5.43”) | 8mm (0.32”) | 4mm (0.16″) | 40mm (1.98″) |
Waterproof Probe – 5m (15’) cable Probe Length: 45mm (1.77”)c |
T456CF2SW-5 | 138mm (5.43”) | 8mm (0.32”) | 4mm (0.16″) | 40mm (1.98″) |
Waterproof Probe – 15m (45’) cable Probe Length: 45mm (1.77”)c |
T456CF2SW-15 | 138mm (5.43”) | 8mm (0.32”) | 4mm (0.16″) | 40mm (1.98″) |
Waterproof Probe – 30m (98’) cable Probe Length: 45mm (1.77”)c |
T456CF2SW-30 | 138mm (5.43”) | 8mm (0.32”) | 4mm (0.16″) | 40mm (1.98″) |
Waterproof Probe – 50m (164’) cable Probe Length: 45mm (1.77”)c |
T456CF2SW-50 | 138mm (5.43”) | 8mm (0.32”) | 4mm (0.16″) | 40mm (1.98″) |
Waterproof Probe – 75m (250’) cable Probe Length: 45mm (1.77”)c |
T456CF2SW-75 | 138mm (5.43”) | 8mm (0.32”) | 4mm (0.16″) | 40mm (1.98″) |
PINIP™ Integral Probe | T456CF2P | 174mm (6.85”) | 8mm (0.32”) | 4mm (0.16″) | 60mm (2.36″) |
Hi-Temperature PINIP™ | T456CF2PHT | 174mm (6.85”) | 8mm (0.32”) | 4mm (0.16″) | 60mm (2.36″) |
Non-Ferrous (N) | |||||
Straight Probe Probe Length: 45mm (1.77”)c |
T456CN2S | 88mm (3.46”) | 14mm (0.55”) | 100mm (3.97″) | 150mm (5.90″) |
PINIP™ Integral Probe | T456CN2P | 185mm (7.28″) | 14mm (0.55”) | 100mm (3.97″) | 150mm (5.90″) |
Scale 3: Range : 0-13mm (0-500mils) | |||||
Accuracya | ±1-3% or ±50μm (±1-3% or ±2.0mils) | ||||
Ranged | 0-13mm (0-500mils) | ||||
Resolution | 1μm: 0-2mm (0.1mil: 0-100mils) 10μm: 2-13mm (1.0mil: 100-500mils) |
||||
Certificate | |||||
Description | Part Number | Minimum Headroom | Minimum Sample Diameterb | Minimum Convex Surface Diameter | Minimum Concave Surface Radius |
Ferrous (F) | |||||
Straight Probe Probe Length: 45mm (1.77”)c |
T456CF3S | 102mm (4.02”) | 14mm (0.55”) | 15mm (0.59″) | 40mm (1.98″) |
PINIP™ Integral Probe | T456CF3P | 184mm (7.24”) | 14mm (0.55”) | 15mm (0.59″) | 45mm (1.77″) |
Non-Ferrous (N) | |||||
Straight Probe Probe Length: 45mm (1.77”)c |
T456CN3S | 170mm (6.69”) | 35mm (1.38”) | Flat Surface | Flat Surface |
Scale FM7: Range: 0.60-3.8mm (25-150mils) | |||||
Accuracya | ±7.5% or ±114μm (±7.5% or ±4.5mils) | ||||
Ranged | 0.60-3.8mm (25-150mils) | ||||
Resolution | 1μm: 0-1mm (0.1mil: 0-139.3mils) 10μm: 1-3.8mm (1.0mil: 39.4-150mils) |
||||
Certificate | |||||
Description | Part Number | Minimum Headroom | Minimum Sample Diameterb | Minimum Convex Surface Diameter | Minimum Concave Surface Radius |
Ferrous (F) | |||||
45° Angle Mini Probe Probe Length: 45mm (1.77”)c |
T456CFM7R45A | 20mm (0.79”) | 6.5 mm (0.26’’) | – | – |
Scale 6: Range : F: 0-25mm (F: 0-980mils) N: 0-30mm (N: 0-1200mils) |
|||||
Accuracya | ±1-3% or ±100μm (±1-3% or ±4.0mils) | ||||
Ranged | F: 0-25mm (F: 0-980mils) N: 0-30mm (N: 0-1200mils) |
||||
Resolution | 10μm: 0-2mm (1mil: 0-100mils) 100μm: 2-30mm (10mils: 100-1200mils) |
||||
Certificate | |||||
Description | Part Number | Minimum Headroom | Minimum Sample Diameterb | Minimum Convex Surface Diameter | Minimum Concave Surface Radius |
Ferrous (F) | |||||
Straight Probe Probe Length: 45mm (1.77”)c |
T456CF6S | 150mm (5.90”) | 51 x 51mm2 (2.17 x 2.17 inch2) | 35mm (1.40″) | 170mm (6.70″) |
Straight Probe – armoured cable Probe Length: 45mm (1.77”)c |
T456CF6ARM | 190mm (7.48”) | 51 x 51mm2 (2.17 x 2.17 inch2) | 35mm (1.40″) | 170mm (6.70″) |
Non-Ferrous (N) | |||||
Straight Probe Probe Length: 45mm (1.77”)c |
T456CN6S | 160mm (6.30”) | 58mm (2.29”) | Flat Surface | Flat Surface |
Straight Probe – armoured cable Probe Length: 45mm (1.77”)c |
T456CN6ARM | 200mm (7.87″) | 58mm (2.29”) | Flat Surface | Flat Surface |
Scale 7: Range : 0-31mm (0-1220mils) | |||||
Accuracya | ±1-3% or ±100μm (±1-3% or ±4.0mils) | ||||
Ranged | 0-31mm (0-1220mils) | ||||
Resolution | 10μm: 0-2mm (1.0mil: 0-100mils) 100μm: 2-31mm (10mils: 100-1220mils) |
||||
Certificate | |||||
Description | Part Number | Minimum Headroom | Minimum Sample Diameterb | Minimum Convex Surface Diameter | Minimum Concave Surface Radius |
Ferrous (F) | |||||
Straight Probe armoured cable Probe Length: 45mm (1.77”)c |
T456CF7ARM | 200mm (7.87″) | 55 x 55mm2 (2.17 x 2.17 inch2) | 40mm (1.58″) | 170mm (6.70″) |
b. FNF (F): FNF probe in F Mode / FNF (N): FNF probe in N
c. Probe length is measured from X to Y
d. Excluding Scan Probe end cap
e. Scan Probe accuracy is ±3% or ±0.02mm (0.8mil) with cap fitted, ±1-3% or ±0.02mm (0.8mil) without cap, when calibrated using a sample of the uncoated substrate
● Test Certificate supplied as standard.
Elcometer 456 Probes are covered by a one-year warranty
-
Elcometer 456 Coating Thickness Gauge 45° Angle Mini Probe – Scale 0.5
- Substrate Probe:Ferrous (F) Probes
- Range:0-500μm, 0-20mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:300mm (11.80”)
- Minimum Headroom:18mm (0.71”)
- Minimum Sample Diameter:3mm (0.12”)
- Part Number : T456CFM3R45D
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe – Scale 0.5
- Substrate Probe:Ferrous (F) Probes
- Range:0-500μm, 0-20mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:300mm (11.80”)
- Minimum Headroom:16mm (0.63”)
- Minimum Sample Diameter:3mm (0.12”)
- Part Number : T456CFM3R90D
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe – Scale 0.5
- Substrate Probe:Ferrous (F) Probes
- Range:0-500μm, 0-20mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:150mm (5.90”)
- Minimum Headroom:16mm (0.63”)
- Minimum Sample Diameter:3mm (0.12”)
- Part Number : T456CFM3R90C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Mini Probe – Scale 0.5
- Substrate Probe:Ferrous (F) Probes
- Range:0-500μm, 0-20mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:150mm (5.90”)
- Minimum Headroom:6mm (0.24”)
- Minimum Sample Diameter:3mm (0.12”)
- Part Number : T456CFM3—C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 45° Angle Mini Probe – Scale 0.5
- Substrate Probe:Ferrous (F) Probes
- Range:0-500μm, 0-20mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:16mm (0.63”)
- Minimum Sample Diameter:3mm (0.12”)
- Part Number : T456CFM3R45A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe – Scale 0.5
- Substrate Probe:Ferrous (F) Probes
- Range:0-500μm, 0-20mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:16mm (0.63”)
- Minimum Sample Diameter:3mm (0.12”)
- Part Number : T456CFM3R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Mini Probe – Scale 0.5
- Substrate Probe:Ferrous (F) Probes
- Range:0-500μm, 0-20mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:6mm (0.24”)
- Minimum Sample Diameter:3mm (0.12”)
- Part Number : T456CFM3—A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe – Scale 0.5
- Substrate Probe:Non-Ferrous (N) Probes
- Range:0-500μm, 0-20mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 400mm (15.70”)
- Minimum Headroom:16mm (0.63”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CNM3R90E
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe – Scale 0.5
- Substrate Probe:Non-Ferrous (N) Probes
- Range:0-500μm, 0-20mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:150mm (5.90”)
- Minimum Headroom:16mm (0.63”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CNM3R90C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Mini Probe – Scale 0.5
- Substrate Probe:Non-Ferrous (N) Probes
- Range:0-500μm, 0-20mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:150mm (5.90”)
- Minimum Headroom:6mm (0.24”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CNM3—C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe – Scale 0.5
- Substrate Probe:Non-Ferrous (N) Probes
- Range:0-500μm, 0-20mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:16mm (0.63”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CNM3R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Mini Probe – Scale 0.5
- Substrate Probe:Non-Ferrous (N) Probes
- Range:0-500μm, 0-20mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:6mm (0.24”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CNM3—A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe – Scale 0.5
- Substrate Probe:Non-Ferrous – Graphite (N)
- Range:0-500μm, 0-20mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 400mm (15.70”)
- Minimum Headroom:16mm (0.63”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CNMG3R90E
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe – Scale 0.5
- Substrate Probe:Non-Ferrous – Graphite (N)
- Range:0-500μm, 0-20mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:150mm (5.90”)
- Minimum Headroom:16mm (0.63”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CNMG3R90C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe – Scale 0.5
- Substrate Probe:Non-Ferrous – Graphite (N)
- Range:0-500μm, 0-20mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:16mm (0.63”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CNMG3R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 45° Angle Mini Probe – Scale FM7
- Substrate Probe:Ferrous (F) Probes
- Range: 0.60-3.8mm, 25-150mils
- Accuracy:±7.5% or ±114μm, ±7,5% or ±4,5mils
- Probe Length:45mm (1.77”)
- Minimum Headroom:20mm (0.79”)
- Minimum Sample Diameter:6.5 mm (0.26’’)
- Part Number : T456CFM7R45A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe – Scale 1
- Substrate Probe:Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:85mm (3.35”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CF1S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Scan Probe – Scale 1
- Substrate Probe:Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom: 86mm (3.38”)
- Minimum Sample Diameter:15mm (0.59”)
- Part Number : T456CF1U
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Scan Probe Armoured – Scale 1
- Substrate Probe:Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:140mm (5.51”)
- Minimum Sample Diameter:15mm (0.59”)
- Part Number : T456CF1UARM
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Probe – Scale 1
- Substrate Probe:Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:28mm (1.10”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CF1R
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Mini Probe – Scale 1
- Substrate Probe:Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:16mm (0.63”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CFM5R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Mini Probe sealed – Scale 1
- Substrate Probe:Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:16mm (0.63”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CFME5R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Mini Probe sealed, 2m cable – Scale 1
- Substrate Probe:Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:16mm (0.63”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CFME5R90A-2
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe – Scale 1
- Substrate Probe:Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Minimum Headroom:170mm (6.69”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CF1P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe – Scale 1
- Substrate Probe:Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:85mm (3.35”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CN1S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe sealed – Scale 1
- Substrate Probe:Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:85mm (3.35”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CF1E
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Probe – Scale 1
- Substrate Probe:Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:28mm (1.10”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CN1R
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Mini 90° Probe – Scale 1
- Substrate Probe:Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:16mm (0.63”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CNM5R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Mini 90° Probe – Scale 1
- Substrate Probe:Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:150mm (5.90”)
- Minimum Headroom:16mm (0.63”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CNM5R90C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Mini 90° Probe – Scale 1
- Substrate Probe:Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 400mm (15.70”)
- Minimum Headroom:16mm (0.63”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CNM5R90E
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe – Scale 1
- Substrate Probe:Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Minimum Headroom:180mm (7.09”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CN1P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Anodiser Probe – Scale 1
- Substrate Probe:Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:100mm (3.94”)
- Minimum Sample Diameter:4mm (0.16”)
- Part Number : T456CN1AS
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe – Scale 1
- Substrate Probe:Ferrous & Non-Ferrous (FNF) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:88mm (3.46”)
- Minimum Sample Diameter:F: 4mm (0.16”), N: 6mm (0.24”)
- Part Number : T456CFNF1S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Scan Probe – Scale 1
- Substrate Probe:Ferrous & Non-Ferrous (FNF) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:89mm (3.50”)
- Minimum Sample Diameter:15mm (0.59”)
- Part Number : T456CFNF1U
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Probe – Scale 1
- Substrate Probe:Ferrous & Non-Ferrous (FNF) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:38mm (1.50”)
- Minimum Sample Diameter:F: 4mm (0.16”), N: 6mm (0.24”)
- Part Number : T456CFNF1R
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe – Scale 1
- Substrate Probe:Ferrous & Non-Ferrous (FNF) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Minimum Headroom:180mm (7.09”)
- Minimum Sample Diameter:F: 4mm (0.16”), N: 6mm (0.24”)
- Part Number : T456CFNF1P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe Armoured Cable – Scale 1
- Substrate Probe:Ferrous & Non-Ferrous (FNF) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy:±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:185mm (7.28″)
- Minimum Sample Diameter:F: 4mm (0.16”), N: 6mm (0.24”)
- Part Number : T456CFNF1ARM
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe – Scale 2
- Substrate Probe:Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy:±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:89mm (3.50”)
- Minimum Sample Diameter:8mm (0.32”)
- Part Number : T456CF2S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe Armoured Cable – Scale 2
- Substrate Probe:Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy:±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:138mm (5.43”)
- Minimum Sample Diameter:8mm (0.32”)
- Part Number : T456CF2ARM
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Scan Probe – Scale 2
- Substrate Probe:Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy:±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:90mm (3.54”)
- Minimum Sample Diameter:15mm (0.59”)
- Part Number : T456CF2U
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Probe – Scale 2
- Substrate Probe:Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy:±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:32mm (1.26”)
- Minimum Sample Diameter:8mm (0.32”)
- Part Number : T456CF2R
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Telescopic Probe – Scale 2
- Substrate Probe:Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy:±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length:56-122cm (22-48”)
- Minimum Headroom:36mm (1.42”)
- Minimum Sample Diameter:8mm (0.32”)
- Part Number : T456CF2T
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Soft Coating Probe – Scale 2
- Substrate Probe:Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy:±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:89mm (3.50”)
- Minimum Sample Diameter:8mm (0.32”)
- Part Number : T456CF2B
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 1m (3’) cable – Scale 2
- Substrate Probe:Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy:±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:138mm (5.43”)
- Minimum Sample Diameter:8mm (0.32”)
- Part Number : T456CF2SW
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 5m (15″) cable – Scale 2
- Substrate Probe:Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy:±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:138mm (5.43”)
- Minimum Sample Diameter:8mm (0.32”)
- Part Number : T456CF2SW-5
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 15m (45″) cable – Scale 2
- Substrate Probe:Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy:±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:138mm (5.43”)
- Minimum Sample Diameter:8mm (0.32”)
- Part Number : T456CF2SW-15
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 30m (98″) cable – Scale 2
- Substrate Probe:Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy:±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:138mm (5.43”)
- Minimum Sample Diameter:8mm (0.32”)
- Part Number : T456CF2SW-30
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 50m (164″) cable – Scale 2
- Substrate Probe:Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy:±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:138mm (5.43”)
- Minimum Sample Diameter:8mm (0.32”)
- Part Number : T456CF2SW-50
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 75m (250″) cable – Scale 2
- Substrate Probe:Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy:±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:138mm (5.43”)
- Minimum Sample Diameter:8mm (0.32”)
- Part Number : T456CF2SW-75
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe – Scale 2
- Substrate Probe:Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy:±1-3% or ±20μm, ±1-3% or ±1.0mil
- Minimum Headroom:174mm (6.85”)
- Minimum Sample Diameter:8mm (0.32”)
- Part Number : T456CF2P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Hi-Temperature PINIP™ – Scale 2
- Substrate Probe:Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy:±1-3% or ±20μm, ±1-3% or ±1.0mil
- Minimum Headroom:174mm (6.85”)
- Minimum Sample Diameter:8mm (0.32”)
- Part Number : T456CF2PHT
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe – Scale 2
- Substrate Probe:Non-Ferrous (N) Probes
- Range: 0-5mm, 0-200mils
- Accuracy:±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length:45mm (1.77”)
- Minimum Headroom:88mm (3.46”)
- Minimum Sample Diameter:14mm (0.55”)
- Part Number : T456CN2S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe – Scale 2
- Substrate Probe:Non-Ferrous (N) Probes
- Range: 0-5mm, 0-200mils
- Accuracy:±1-3% or ±20μm, ±1-3% or ±1.0mil
- Minimum Headroom:185mm (7.28″)
- Minimum Sample Diameter:14mm (0.55”)
- Part Number : T456CN2P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe – Scale 3
- Substrate Probe:Ferrous (F) Probes
- Range: 0-13mm, 0-500mils
- Accuracy:±1-3% or ±50μm, ±1-3% or ±2.0mils
- Probe Length:45mm (1.77”)
- Minimum Headroom:102mm (4.02”)
- Minimum Sample Diameter:14mm (0.55”)
- Part Number : T456CF3S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe – Scale 3
- Substrate Probe:Ferrous (F) Probes
- Range: 0-13mm, 0-500mils
- Accuracy:±1-3% or ±50μm, ±1-3% or ±2.0mils
- Minimum Headroom:184mm (7.24”)
- Minimum Sample Diameter:14mm (0.55”)
- Part Number : T456CF3P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe – Scale 3
- Substrate Probe:Non-Ferrous (N) Probes
- Range: 0-13mm, 0-500mils
- Accuracy:±1-3% or ±50μm, ±1-3% or ±2.0mils
- Probe Length:45mm (1.77”)
- Minimum Headroom:170mm (6.69”)
- Minimum Sample Diameter:35mm (1.38”)
- Part Number : T456CN3S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe – Scale 6
- Substrate Probe:Ferrous (F) Probes
- Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
- Accuracy:±1-3% or ±100μm, ±1-3% or ±4.0mils
- Probe Length:45mm (1.77”)
- Minimum Headroom:150mm (5.90”)
- Minimum Sample Diameter:51 x 51mm2 (2.17 x 2.17 inch2)
- Part Number : T456CF6S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe armoured cable – Scale 6
- Substrate Probe:Ferrous (F) Probes
- Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
- Accuracy:±1-3% or ±100μm, ±1-3% or ±4.0mils
- Probe Length:45mm (1.77”)
- Minimum Headroom:190mm (7.48”)
- Minimum Sample Diameter:51 x 51mm2 (2.17 x 2.17 inch2)
- Part Number : T456CF6ARM
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe – Scale 6
- Substrate Probe:Non-Ferrous (N) Probes
- Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
- Accuracy:±1-3% or ±100μm, ±1-3% or ±4.0mils
- Probe Length:45mm (1.77”)
- Minimum Headroom:160mm (6.30”)
- Minimum Sample Diameter:58mm (2.29”)
- Part Number : T456CN6S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe armoured cable – Scale 6
- Substrate Probe:Non-Ferrous (N) Probes
- Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
- Accuracy:±1-3% or ±100μm, ±1-3% or ±4.0mils
- Probe Length:45mm (1.77”)
- Minimum Headroom:200mm (7.87″)
- Minimum Sample Diameter:58mm (2.29”)
- Part Number : T456CN6ARM
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe armoured cable – Scale 7
- Substrate Probe:Ferrous (F) Probes
- Range: 0-31mm, 0-1220mils
- Accuracy:±1-3% or ±100μm, ±1-3% or ±4.0mils
- Probe Length:45mm (1.77”)
- Minimum Headroom:200mm (7.87″)
- Minimum Sample Diameter:55 x 55mm2 (2.17 x 2.17 inch2)
- Part Number : T456CF7ARM
- Certification : Test Certificate